Sc 2201 manual




















Strong Movable Shelves Capacity: L Power Input: W. We use cookies to collect and analyze information on site performance and usage, to provide social features and to enhance and customise content and advertisements. Learn More. ID EN. Shopping Cart. Items Total. Showcase Cooler - Finestra SC L Rp22,, Heavy duty showcase cooler with 2 layered glass door, self evaporation, hot air, and heavy duty compressor.

Energy Efficiency 4. Sorry, the product is currently out of stock. Interior Light Interiors are easier to see thanks to subtle and efficient illumination.

Temperature Display Easily monitor the inside of the showcase with a temperature display. Showcase Cooler - Finestra. Size Width: mm Depth: mm Height: mm Weight: kg. Features 1. Including 1. Showcase Cooler. Self Evaporation. Label the existing wires with the enclosed wire labels before removing wires.

See table below for old and new label identification. To reset the system, turn thermostat to Off position for at least 60 seconds. Note: Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall, in direct sunlight, behind a door, or in an area affected by a vent or duct.

Page 8: Testing The Thermostat Insert stripped, labeled wires in matching wire terminals. See Wiring Diagrams section of this manual Pages Tighten screws on terminal block. Gently tug wire to be sure of proper connection.

Double check that each wire is connected to the proper terminal. Seal hole for wires with non-flammable putty or insulation. Replace cover on thermostat by snapping it in place.

Turn on power to the system at the main service panel. Test thermostat operation as described in the following section.

This can damage the air conditioning system and may cause personal injury. Put the Mode switch to Cool position.

Mode 2. Press the button until the temperature setting is at least 3 degrees below the room temperature. The air conditioning system and fan should turn on within a few seconds. Cool Off Heat Emer 3. Put the Mode switch in the Off position. The air conditioning system should turn off. The fan may have a delay. Mode Note: Pressing the Reset button will bypass the 5-minute anti-short cycle compressor protection.

Page 9 Note: While in Cool or Heat mode, once the thermostat turns the system off, a built-in delay keeps the compressor from turning on for about 5 minutes. This protects the compressor. Mode 4. Put the Mode switch to the Heat position. Press the button until the temperature setting is at least 3 degrees above room Cool Off Heat Emer temperature. The heating system should turn on.

Note: The compressor may not turn on again for 5 minutes. Mode 6. Put the Mode switch to the Off position. The heating system should turn off. Once again the fan may have a delay. Cool Off Heat Emer 7. Put the Fan switch to the On position. The blower fan should turn on.

Auto 8. Put the Fan switch to the Auto position. The blower fan should turn off. If all functions operate properly, the thermostat is installed correctly.

This is the second non-economy stage of heat. It turns on 2 degrees below first stage and is not adjustable. Please contact a qualified service technician as soon as possible to check your system. While in the emergency heat mode, the heat pump compressor is off, and the emergency heat same as the auxiliary heat maintains the setpoint temperature.